Optimization of an Integrated Filter Photometric system and a Centrifugal Microfluidic System for Biochemical Analysis
Authors :
Bahareh Mohammadi Jobani
1
Amin Dehghan
2
Zahra Shahsavari
3
Esmail Pishbin
4
1- دانشگاه علوم پزشکی شهید بهشتی
2- دانشگاه علم و صنعت ایران
3- دانشگاه علوم پزشکی شهید بهشتی
4- سازمان پژوهش علمی و صنعتی ایران
Keywords :
Filter photometers،POCT،Centrifugal microfluidics،Siphon valves،Biochemical markers
Abstract :
Microfluidic systems are rapidly advancing, particularly when integrated with medical science to enhance laboratory services. Key benefits of microfluidics, such as portability, the ability to multiplex several tests, and low reagent requirements, create a broad research area, especially in laboratory detection systems. Photometer-based analyzers are the most common detectors for medical tests, including absorbance and fluorescence-based detectors that cover a wide range of detection analyses. This study aimed to develop an optimized centrifugal microfluidic system integrated with a custom vertical filter-photometer. The compact design, which incorporates miniaturized filters and lenses, was engineered to achieve a precision and accuracy comparable to commercial autoanalyzers. For this purpose, a centrifugal microfluidic device was designed and optimized with a focus on siphon channel actuation for biochemical analysis. Human serum samples, with previously analyzed biomarker data, were obtained from the Parseh lab. To validate the microfluidic and the optical setup's functionality, three common metabolic tests were selected: glucose, triglycerides, and cholesterol. Human serum was injected into the disc, and the subsequent analysis, along with the calibrator test, was performed on the same disc. The results of light absorbance for these tests on disc microfluidic using the optical setup showed a high correlation (R² above 0.99 for all three tests) with the reported results from the Parseh lab, which served as the reference. Finally, to minimize the bias observed between our results and the reference results, an algorithm was developed to predict optimized data for new tests. Based on the findings, this filter photometer setup has the potential to be enhanced with additional filters for comprehensive biochemical tests analyzed through optical absorbance systems, and along with optimized microfluidic devices, can be introduced for POCT systems.
Papers List
List of archived papers
سامانه ی یکپارچه و کمهزینه برای ثبت پتانسیلهای میدانی محلی (LFP) همگام با ویدئو و تحریک الکتریکیِ مغز بهکمک برچسبگذاری نوریِ کُدگذاریشده ی رخداد
حنیف صولت نیا - بیژن وثوقی وحدت
Fixed-Frequency Impedimetric Detection of Sickle Cells Using Interdigitated Electrodes
َArezoo Savlani - Mobina Ghanbari - Mohammadjavad Bouloorchi Tabalvandi - Majid Badieirostami
Investigating the effect of alpha/theta neurofeedback on Emotional Intelligence
Saeed Yarmohammadi - Amirreza Ahmadi
پلتفرم هوشمند «دستیار پیمانکار»
محمد عبدالهی سنو
تاثیر ویژگی های کمیته حسابرسی و حسابرس داخلی بر به موقع بودن گزارشگری مالی
غلامعلی شریفی
نقش ارزیابی عملکرد در مدیریت صحیح منابع انسانی (با تاکید بر نقش مدیران میانی)
محمد خدایی قلقاچی
خطرات احتمالی در طراحی و تجزیه و تحلیل سیستمهای حسابداری و راهکارهای مقابله با آن
علی نمازیان - آرزو رضایی حومدینی
Biomechanical Evaluation and Comparison of Spinal Fixators in the Lumbar (L3–L4) Region Using the Finite Element Method
Nima Moazed - Mohammad Haghpanahi
Multi-Objective Optimization of the Impeller of a mini Blood Pump: Balancing Outlet Pressure and Scalar Shear Stress
Reza Sahebi-Kuzeh kanan - Hanieh Niroomand-oscuii - Habib Badri Ghavifekr - Farzan Ghalichi
سامانه هوشمند مبتنی بر بینایی ماشین برای تشخیص افتادن سالمندان: رویکردی ایمن، دقیق و سریع
سیدحسن نوری - هدی محمدزاده
more
Samin Hamayesh - Version 42.4.6